Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study

Source avec lien : BMJ Open, 10(7), 7/1/2020. 10.1136/bmjopen-2020-039120

Objectif Développer et tester un nouveau masque respiratoire filtrant réutilisable et stérilisable, comparable au masque N95, connu sous le nom de système iMASC (Injection Molded Autoclavable, Scalable, Conformable), étant donné le besoin urgent d’équipements de protection individuelle dans les établissements de santé pendant la pandémie COVID-19.

Objective To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. Design Single-arm feasibility study. Setting Emergency department and outpatient oncology clinic. Participants Healthcare workers who have previously undergone N95 fit testing. Interventions Fit testing of new iMASC system. Primary and secondary outcome measures Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. Results Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21–65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. Conclusions The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.

Lisez l’article

Laisser un commentaire