Source avec lien : Journal of Occupational and Environmental Hygiene, (En ligne). 10.1080/15459624.2022.2100408
Cette étude porte sur le retraitement d’un groupe de masques respiratoires filtrants (FFR) en utilisant l’irradiation germicide ultraviolette (UVGI). L’objectif est d’explorer la possibilité de désinfecter certains FFR KN95, par rapport aux FFR N95, et d’évaluer leur viabilité pour une réutilisation.
This study focuses on reprocessing a group of filtering facepiece respirators (FFR) using ultraviolet germicidal irradiation (UVGI). The aim is to explore the possibility of disinfecting selected KN95 FFRs, in comparison with the N95 FFRs, and assess their viability for reusage. For this purpose, five models of unused N95 and KN95 FFR models obtained from the hospital were exposed to UV-C light using a customized UVGI chamber. The material integrity of treated FFRs was examined in terms of particle penetration and strap tension. The surface morphology of all models is inspected to determine the visible changes of each FFR upon exposure to 1–100 cycles (1 cycle is equivalent to 1 J/cm2 UV dose). The penetration test results indicate that the physical properties of the KN95 and N95 FFRs remain within permissible limits despite being reprocessed by up to 100 cycles (100 J/cm2). Using a microscope, the physical observations also reveal that no visible damage can be seen even after 100 J/cm2 exposure. Apart from the filter bodies, the tension of each strap was also found to not be significantly affected by UV radiation by at least 10 disinfection cycles (10 J/cm2). This confirms that KN95, as well as N95 FFRs, can be subjected to UV treatment as a means of disinfection.